ECON/O/GLIDE
AUTOMATIC POWER DOOR (APD)
RMI automatic
doors are specifically designed for use in cold storage rooms. State-of-the-art
motion and presence sensors open and shut the room doors for convenient, hands-free access.
ONLY RMI OFFERS
ALL THESE FEATURES:
DOPPLER
RADAR MOTION DETECTORS
Dual
K-Band Radar automatically opens the door from the inside and outside.
Inside and outside
motion arrays are independently adjustable for pick-up distance as well as
side-to-side bias, and can be set for increased sensitivity to motion from one
side of the door to the other. They reliably sense motion from less than 18
inches to more than 6.5 feet from the door.
INFRARED
PRESENCE SENSORS
Dual
and independently adjustable, they provide an invisible safety curtain on the
door’s inside and outside, preventing the door from closing on slow moving
personnel and objects.
MOTION
DETECTORS
Selectable
unidirectional or bi-directional motion detection on each detector. The
unidirectional setting senses any object moving towards the door and ignores
objects moving away from the door.
AUTOMATIC
DIGITAL SIGNATURE
Analysis
allows the door protection and motion system to learn the background and the
door motion pattern. This feature allows the door electronics to ignore
items you place near the door face.
REMOTE
PROGRAM CONTROL
Hand-held,
battery powered (similar to a television control), with a digital access code
lock. This control can program door opening and sensing parameters.
Door hold-open time can be adjusted with the remote from 0.5 to 9.0
seconds. Longer hold-open times can be provided by adjusting the
factory Preset Door Programmed Microprocessor Control Program (PLC).
 
KEY
SWITCH
Allows
an authorized operator to set the door to “OFF”, “AUTO” or “OPEN”.
In “OFF” Position – The door is held actively closed and will not respond
to the outside motion sensor or outside presence sensor. The door is
still
opened by the inside motion sensor and the inside access switch. In the “AUTO” Position – The door
operates from the motion and presence detectors. In the “OPEN”
Position - The door remains open until returned to the “OFF” or “AUTO”
positions. In this key position, the door can be freewheeled for adjustment or
maintenance.
AUTOMOBILE-STYLE
ELECTRICAL CONNECTORS
Central
circuit board wiring and shielded electrical cables all contribute to rapid
field service and part replacement, if necessary.
PROGRAMMED
MICROPROCESSOR
Controls
motor, door and motion sensor operation.
BRUSHLESS
DC MOTOR
Highly
reliable with only one moving part. The motor's rotor is suspended from
both
forward and rear ball bearing races for extremely long life.
ELECTRONIC
DYNAMIC BREAKING
Quickly
reduces door speed near the end of travel.
ELECTRONIC
TORQUE LIMITS
Protects
working personnel from excessive door closing force.
CONTROLLED
DOOR ACCELERATION
Assures
smooth door opening and closing by controlling door acceleration and
deceleration.
CAPACITIVE
PRESSURE SENSITIVE SWITCH
An
interior switch with a constant burning LED light activates the door from the
inside even when the key switch is in the “OFF” position.
MANUAL
OPENING
Free
wheeling manual opening in the event of a power failure.
SEALING
GASKET
Magnetic,
central sealing gasket.
PHOTO-OPTICAL
SENSING
Senses
the door position.
LOW
VOLTAGE
DC,
motion sensing, key switch, and interior switch wiring.
ADJUSTABLE
ECCENTRIC CAM-ROLLER
Located
on each door assures that the doors meet uniformly along the vertical
centerline.
POLYURETHANE
TIMING BELT
Steel
reinforcing guarantees the long term reliability of the door drive system.
EASY
CLEANING
Two
interlocked removable front covers allow easy access. The door is also available without
front covers.
BOLLARDS
Stainless
steel, tubular.

OPERATIONAL
DESCRIPTION
External Wizard –
Located above the door, outside the chamber. Detects people and/or objects
approaching the door from the outside and remaining near the door opening just
outside the door.
Internal Wizard –
Located above the door, inside the chamber.
Detects people and/or objects approaching the door from the inside and
remaining near the door opening just inside the door.
Inside Safety Switch –
Located on the inside of the chamber to the right of the door (as viewed from
the inside looking out). Illuminated,
the switch is operated by finger pressure on the center of the disk, just
below the red LED.
ALARMS
Type
1 – A single chirp alarm is
generated when the door fails to move because of an obstruction, excess
friction, or drive failure. The alarm will automatically clear in 30 seconds.
Type
2 – A double chirp alarm is
generated when the door position sensors detect an abnormal condition, usually
by removing the upper door fascia. The alarm will automatically clear in 30
seconds.
Type
3 – A triple chirp alarm is
generated when the door is opened by the internal wizard, the internal
safety switch, or is forced open while the key is in the off position. The
alarm will not automatically clear; it requires a key.
OPERATION
Power
Up – When the door is
initially powered up it will move to the position set by the key. The internal
and external wizards will initialize, causing the door to open and close,
while they learn the optical characteristics of a clear doorway. It is
important that no objects or people
enter the detect field of either wizard during this time.
Key
“OFF” – Until the door is in the closed position the door will operate as
though the key is set to “AUTO.” Once closed, the door will not respond to
the external wizard. If the internal wizard or the internal safety switch is
operated, the door will open and a Type
3 alarm will be generated. Also, a Type 3 alarm will be generated if the door
is forced open.
Key
“AUTO” – The door opens in response to either the external or the internal
wizard and the internal safety switch. The controller sets the length of time
the door remains open; factory set at 2 seconds. The door will remain open
while the wizards detect the approach
or presence of people and/or objects and will close following a programmed
delay after approach or presence is no longer detected.
Key
“OPEN” – The door will open. Once opened the door will deactivate.
Once
deactivated it will move only if pushed or pulled by hand.

SPECIFICATIONS
Door
Panel Finish: 20 gauge
stainless steel, type 304, #4 finish.
Exterior
Frame Metal: 20 gauge stainless
steel, type 304, #4 finish.
Interior
Frame Metal: Same as specified
for wall panels.
Door
and Frame Insulation: Same as
specified for RMI walk-in.
Removable
Front Enclosure: 16 gauge
stainless steel.
Door
Components and Operating Features:
•
Remotely Programmable.
•
Interior Safety Release.
•
Motion Detector.
•
Presence Detector.
•
Key Lockable.
•
Manual Override.
•
Heated Windows.
•
Heated Frame and Door Panels.
Please see our Literature,
Specifications
and Drawing Download Page for additional information on some of the items you may wish to consider when evaluating a new
requirement or system need. For more information, you can contact us by using our
Feedback Form, E-Mail or
Calling Us directly by telephone. We are happy to help.
 

|